YJLV32

These power cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. They are suitable for laying Indoor, tunnel, cable trench, shaft or buried laying, The cable can withstand mechanical external forces and a certain tensile force, it widely used in transformer stations, electric power plants and industrial plants.

key word:

YJLV32

Product Description

APPLICATION

These power cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. They are suitable for laying Indoor, tunnel, cable trench, shaft or buried laying, The cable can withstand mechanical external forces and a certain tensile force, it widely used in transformer stations, electric power plants and industrial plants.

CONSTRUCTION

● Conductor: Aluminum, class 1 or class 2, solid or stranded, circular or circular compacted conductors

● Insulation: Cross-linked polyethylene XLPE

● Filler: Non-hygroscopic material

● Binder: Non-hygroscopic material

● Inner sheath: Polyvinyl chloride PVC

● Armour: Steel wire

● Binder: Non-hygroscopic material

● Outer sheath: Polyvinyl chloride PVC

MAIN CHARACTERRISTICS

Good electrical and mechanical properties. Cross-linked polyethylene insulation allows greater power capacity under any operating condition, minimum dielectric losses, high insulation resistance. The PVC outer sheath allows an adequate resistance to oil and abrasion.

SPECIFICATION

IEC 60228 Conductors of Insulate Cables

IEC 60502-1 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1: Cables for Rated Voltages of 1kV (Um=1.2kV) and 3kV(Um=3.6kV)

YJLV32

No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Nominal Approx. Approx. Weight Max. D.C. Resistance of Conductor
Steel Wire Diameter Sheath Thickness Overall Diameter at 20℃
No. × mm² No. mm mm mm mm kg/km Ω/km
2×2.5 1 0.7 0.8 1.8 14.1 314 12.1
2×4 1 0.7 0.8 1.8 15.1 357 7.41
2×6 1 0.7 0.8 1.8 16.1 406 4.61
2×10 6 0.7 1.25 1.8 19.5 619 3.08
2×16 6 0.7 1.25 1.8 21.1 743 1.91
2×25 6 0.9 1.6 1.8 25 1078 1.2
2×35 6 0.9 1.6 1.8 27 1243 0.868
2×50 6 1 1.6 1.8 30 1459 0.641
2×70 12 1.1 1.6 2 33.8 1796 0.443
2×95 15 1.1 2 2.1 39.1 2495 0.32
2×120 15 1.2 2 2.2 42.5 2836 0.253
2×150 15 1.4 2 2.3 46.5 3330 0.206
2×185 30 1.6 2.5 2.5 52.3 4386 0.164
2×240 30 1.7 2.5 2.7 57.7 5192 0.125
2×300 30 1.8 2.5 2.8 63.1 6049 0.1
2×400 53 2 2.5 3.1 70.1 7194 0.0778
3×2.5 1 0.7 0.8 1.8 14.6 340 12.1
3×4 1 0.7 0.8 1.8 15.6 388 7.41
3×6 1 0.7 0.8 1.8 16.7 448 4.61
3×10 6 0.7 1.25 1.8 20.4 682 3.08
3×16 6 0.7 1.25 1.8 22.1 835 1.91
3×25 6 0.9 1.6 1.8 26.2 1221 1.2
3X35 6 0.9 1.6 1.8 28.4 1414 0.868
3×50 6 1 1.6 1.9 31.8 1681 0.641
3×70 12 1.1 2 2 37.2 2389 0.443
3×95 15 1.1 2 2.2 41.5 2895 0.32

 

No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Nominal Approx. Approx. Weight Max. D.C. Resistance of Conductor
Steel Wire Diameter Sheath Thickness Overall Diameter at 20℃
No. × mm² No. mm mm mm mm kg/km Ω/km
3×120 15 1.2 2 2.3 45.2 3336 0.253
3×150 15 1.4 2.5 2.5 51.1 4415 0.206
3×185 30 1.6 2.5 2.6 55.6 5113 0.164
3×240 30 1.7 2.5 2.8 61.8 6188 0.125
3×300 30 1.8 2.5 3 67.4 7206 0.1
3×400 53 2 2.5 3.2 74.7 8623 0.0778
4×2.5 1 0.7 0.8 1.8 15.4 377 12.1
4×4 1 0.7 0.8 1.8 16.6 436 7.41
4×6 1 0.7 1.25 1.8 18.7 631 4.61
4×10 6 0.7 1.25 1.8 21.8 779 3.08
4×16 6 0.7 1.6 1.8 24.4 1076 1.91
4×25 6 0.9 1.6 1.8 28.3 1404 1.2
4×35 6 0.9 1.6 1.9 30.9 1645 0.868
4×50 6 1 1.6 2 34.7 1977 0.641
4×70 12 1.1 2 2.2 40.7 2829 0.443
4×95 15 1.1 2 2.3 45.3 3434 0.32
4×120 15 1.2 2.5 2.5 51 4442 0.253
4×150 15 1.4 2.5 2.6 55.8 5198 0.206
4×185 30 1.6 2.5 2.8 61.4 6194 0.164
4×240 30 1.7 2.5 3 67.9 7424 0.125
4×300 30 1.8 2.5 3.2 74.1 8695 0.1
4×400 53 2 3.15 3.5 84.1 11526 0.0778
5×2.5 1 0.7 0.8 1.8 16.3 419 12.1
5×4 1 0.7 1.25 1.8 18.5 606 7.41
5×6 1 0.7 1.25 1.8 19.9 704 4.61
5×10 6 0.7 1.25 1.8 23.3 870 3.08
5×16 6 0.7 1.6 1.8 26.1 1227 1.91
5×25 6 0.9 1.6 1.8 30.5 1597 1.2
5×35 6 0.9 1.6 1.9 33.4 1890 0.868
5×50 6 1 2 2.1 39.3 2609 0.641

 

No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Nominal Approx. Approx. Weight Max. D.C. Resistance of Conductor
Steel Wire Diameter Sheath Thickness Overall Diameter at 20℃
No. × mm² No. mm mm mm mm kg/km Ω/km
5×70 12 1.1 2 2.3 44.3 3271 0.443
5×95 15 1.1 2.5 2.5 51 4494 0.32
5×120 15 1.2 2.5 2.6 55.5 5148 0.253
5×150 15 1.4 2.5 2.8 61.4 6181 0.206
5×185 30 1.6 2.5 3 67.2 7236 0.164
5×240 30 1.7 2.5 3.2 74.4 8761 0.125
5×300 30 1.8 3.15 3.4 82.9 11266 0.1
5×400 53 2 3.15 3.8 92.4 13590 0.0778
3×4+1×2.5 1/1 0.7/0.7 0.8 1.8 16.3 422 7.41/12.1
3×6+1×4 1/1 0.7/0.7 1.25 1.8 18.4 608 4.61/7.41
3×10+1×6 6/1 0.7/0.7 1.25 1.8 21 736 3.08/4.61
3×16+1×10 6/6 0.7/0.7 1.25 1.8 23.2 905 1.91/3.08
3×25+1×16 6/6 0.9/0.7 1.6 1.8 27.3 1321 1.20/1.91
3×35+1×16 6/6 0.9/0.7 1.6 1.8 29.1 1489 0.868/1.91
3×50+1×25 6/6 1.0/0.9 1.6 1.9 33 1831 0.641/1.20
3×70+1×35 12/6 1.1/0.9 2 2.1 38.6 2584 0.443/0.868
3×95+1×50 6/15 1.1/1.0 2 2.2 43 3114 0.320/0.641
3×120+1×70 12/15 1.2/1.1 2 2.4 47.3 3683 0.253/0.443
3×150+1×70 12/15 1.4/1.1 2.5 2.5 52.4 4719 0.206/0.443
3×185+1×95 30/15 1.6/1.1 2.5 2.7 57.5 5527 0.164/0.320
3×240+1×120 30/15 1.7/1.2 2.5 2.9 63.8 6672 0.125/0.253
3×300+1×150 30/15 1.8/1.4 2.5 3 69.5 7800 0.100/0.206
3×400+1×185 53/30 2.0/1.6 3.15 3.3 78.8 10313 0.0778/0.164
3×4+2×2.5 1/1 0.7/0.7 1.25 1.8 18 577 7.41/12.1
3×6+2×4 1/1 0.7/0.7 1.25 1.8 19.3 660 4.61/7.41
3×10+2×6 6/1 0.7/0.7 1.25 1.8 21.9 807 3.08/4.61
3×16+2×10 6/6 0.7/0.7 1.6 1.8 25.3 1138 1.91/3.08
3×25+2×16 6/6 0.9/0.7 1.6 1.8 28.7 1450 1.20/1.91
3×35+2×16 6/6 0.9/0.7 1.6 1.8 30.4 1614 0.868/1.91
3×50+2×25 6/6 1.0/0.9 2 2 36.4 2285 0.641/1.20

 

No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Nominal Approx. Approx. Weight Max. D.C. Resistance of Conductor
Steel Wire Diameter Sheath Thickness Overall Diameter at 20℃
No. × mm² No. mm mm mm mm kg/km Ω/km
3×70+2×35 12/6 1.1/0.9 2 2.1 40.4 2814 0.443/0.868
3×95+2×50 6/15 1.1/1.0 2 2.3 45.4 3436 0.320/0.641
3×120+2×70 12/15 1.2/1.1 2.5 2.5 51.6 4566 0.253/0.443
3×150+2×70 12/15 1.4/1.1 2.5 2.6 54.9 5099 0.206/0.443
3×185+2×95 30/15 1.6/1.1 2.5 2.8 60.9 6138 0.164/0.320
3×240+2×120 30/15 1.7/1.2 2.5 3 67 7316 0.125/0.253
3×300+2×150 30/15 1.8/1.4 2.5 3.2 73.4 8591 0.100/0.206
3×400+2×185 53/30 2.0/1.6 3.15 3.5 83 11345 0.0778/0.164
4×4+1×2.5 1/1 0.7/0.7 1.25 1.8 18.2 587 7.41/12.1
4×6+1×4 1/1 0.7/0.7 1.25 1.8 19.6 682 4.61/7.41
4×10+1×6 6/1 0.7/0.7 1.25 1.8 22.6 838 3.08/4.61
4×16+1×10 6/6 0.7/0.7 1.6 1.8 25.7 1182 1.91/3.08
4×25+1×16 6/6 0.9/0.7 1.6 1.8 29.6 1515 1.20/1.91
4×35+1×16 6/6 0.9/0.7 1.6 1.9 32 1750 0.868/1.91
4×50+1×25 6/6 1.0/0.9 2 2.1 38 2485 0.641/1.20
4×70+1×35 12/6 1.1/0.9 2 2.2 42.4 3054 0.443/0.868
4×95+1×50 6/15 1.1/1.0 2 2.4 47.5 3726 0.320/0.641
4×120+1×70 12/15 1.2/1.1 2.5 2.5 53.4 4843 0.253/0.443
4×150+1×70 12/15 1.4/1.1 2.5 2.7 57.9 5608 0.206/0.443
4×185+1×95 30/15 1.6/1.1 2.5 2.9 64 6702 0.164/0.320
4×240+1×120 30/15 1.7/1.2 2.5 3.1 70.7 8012 0.125/0.253
4×300+1×150 30/15 1.8/1.4 3.15 3.3 79 10410 0.100/0.206
4×400+1×185 53/30 2.0/1.6 3.15 3.6 87.6 12438 0.0778/0.164